Installation Instructions

This page contains installation instructions for many of ERI’s standard products. Please note, that the nature of the products ERI manufactures often calls for custom modifications or unique installation criteria and methods. In all cases, the installation documentation included with the shipment of any ERI or vendor-supplied products and any operating, maintenance, or inspection manuals or other warnings and instructions, including labels and signs affixed to the product or its packaging supersedes any instructions or warnings included in this library of publications. The same statement applies to instructions provided by ERI via email or other means during installation and/or subsequent repairs.

For the convenience of current users, this library includes installation instructions for some products that have been discontinued or have updated designs. In these cases, the installation instructions and other documentation that was current at the time shipment is considered to be correct and current. In all cases, the specifications presented in published literature and manuals are typical, and total system performance may vary.  In a continuing effort to improve products, ERI reserves the right to change specifications and features.

100A Series FM Antenna

Installation Instructions - 100A Series Low Power FM Antenna Type 100A-1M, 100A-2F, 100A-2F-HW, 100A-4F, and 100A-4F-HW Low Power FM antenna. Note that if special configurations or directional FM arrays should follow the installation instructions and drawings that are included with the antenna shipment.

Download File

1329Line™ Rigid Coaxial Transmission Line

Installation Instructions for 1329Line™ rigid transmission line sizes: 3-1/8-inch, 4-1/16-inch, and 6-1/8-inch (50-ohm and 75-ohm) the associated ERI manufactured hangers and other support products and accessories applicable to these systems.

Download File

Clamp Type Field Flange Kits for Rigid Coaxial Transmission Lines Types RLA000-38, RLA100-38, 1329100­-38, RLA300-38, CA301, RLA400-38, 1329400­-38, RLA600B­-38, and 1329600-38

The Clamp Type Kits in this series are designed for use with flanged and unflanged ERI Standard Line and unflanged 1329Line™ rigid coaxial transmission line for unpressurized applications. Since they are unpressurized, they are intended for use inside buildings and they would rarely be used with MACXLine®. Cutback dimensions for use with MACXLine® must be taken from MACXLine® installation instructions. The kit includes a fixed ring flange and clamp, order inner connector and flange hardware separately. ERI Installation Bulletin II23006-CL1.

Download File

Connectors, 4-1/16 inch 50 Ohm Flanged for HELIAX® HJ11-50 Coaxial Cable Types H11FB-401E, H11FP-401E, H11MB-401E, and H11MP-401E

Installation Instructions - Connectors, 4-1/16 inch 50 Ohm Flanged for HELIAX® HJ11-50 Coaxial Cable Types H11FB-401E, H11FP-401E, H11MB-401E, and H11MP-401E

Download File

EIA Flange Adapters For Connecting 3-1/8 inch 50 Ohm EIA to 1-5/8 inch 50 Ohm EIA Type RLA350-150 Reducer

Reducers are designed to join flanged transmission lines of different diameters. The RLA350-150 reducer has a removable 1-5/8” 50 ohm inner connector, but the 3-1/8” 50 ohm side requires a female 3-1/8” connection.

Download File

EIA Flange Adapters for Rigid Transmission Lines Types RLA050-NF, RLA150-NF, & RLA350-NF and RLA050-LC & RLA150-LC

The adapters are used to join EIA flanged transmission line to Types N or LC Plugs on coaxial cables. A gas barrier and gas port with removable vent plug are incorporated.

Download File

End Terminals For Coaxial Cable and Rigid Transmission Lines Types RLA150-80 (1-5/8 in.) and RLA350-80 (3-1/8 in.)

These end terminals are designed for use with air-dielectric HELIAX® 50-ohm coaxial cable and 50-ohm rigid transmission line. They provide a pressure termination for the air-dielectric transmission line and terminate with a threaded stud. A strap connection is made to this stud for various applications, such as to an antenna or a transmitter. Each end terminal has a gas barrier and a gas port with a removable vent plug.

Download File

Feed-Thru Flange Kits, Types 33938-1, 33938-2, 33938-3, 33938-4, 33938-5

The Feed-Thru Flange provides a weatherproof path through a roof or wall for HELIAX® cable. A path for an accompanying antenna power cord is also provided. The flange can be mounted to metal or concrete.

Download File

Field Cut MACXLine® Rigid Coaxial Line 5 to 20 Foot Lengths Type MACX450-39, MACX450-39W, MACXB675-39 and MACX675B-39W

Typed MACX450-39, MACX450-39W, MACX675B-39 and MACX675B-39W Rigid Coaxial Transmission Line sections are used for field trimming to a nonstandard length between 5 and 20 feet. These products each include an outer conductor with one flange attached, a fixed flange (for silver brazing attachment), a 20 ft inner conductor section with bullet and bellows assembly, insulators, and hardware kit.

Download File

Field Cut Straight Sections for MACXLine® Rigid Coaxial Transmission Lines Type MACX650-39

Type MACX650-39 MACXLine Field Cut Straight Sections are used for non-standard length between 5 and 20 feet. MACX650-39 consists of: an outer conductor with one flange attached, fixed flange, and a 20 ft inner conductor section with bullet-bellows assembly, insulators, and hardware. The inner and outer conductors are field cut to the desired length to suit the rigid line system layout. After trimming the outer conductor, the fixed flange is soldered on. The inner conductor, which is cut to match, has provision for attaching the bullet-bellows assembly to either end. This feature eliminates the need to solder a stub to the inner conductor when the length requirement conflicts with support insulator locations. The inner conductor is marked with black ink to designate specific areas where cutting requires a special bellows relocation procedure. This procedure applies only to section flange-to-flange lengths of 161-1/8" to 165-1/8" and 81-7/8" to 85-7/8".

Download File

Field Kit for MACXLine® Rigid Lines 5 to 20 Foot Lengths Type MACX675B-39

Type MACX675B-39 Rigid Field Kits are used for field trimming to a nonstandard length between 5 and 20 feet. Type MACX675B-39 Field Kits are supplied with an outer conductor with one flange attached, fixed field flange (for attachment), 20 ft inner conductor section with bullet and bellows assembly, insulators, and hardware kit. The inner and outer conductors must be field cut to the desired length to fit into the rigid line installation. The outer conductor must be trimmed and the fixed flange soldered to the cut end.

Download File

Field Kits for Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Types MACX675A-26 and MACX450-26

Type MACX675B-26 Rigid Field Kits are used for field trimming inner conductors to a non-standard length between 5 and 20 feet. Type MACX675B-26 Inner Conductors are supplied as an entire 20 foot inner conductor section with bellows, insulators, captivating inner connector, and hardware kit. The inner conductor must be field cut to the desired length to mate with the corresponding outer conductor.

Download File

Fine Tuner Kits For STD and MACXLine® 6-1/8 “, 7-3/16”, & 8-3/16” Rigid Coaxial Transmission Lines Types RLA650B-FTK, RLA675B-FTK, RLA775-FTK and RLA875B-FTK

ERI Fine Tuner Kits are used to improve the VSWR of existing Rigid Coaxial Transmission Lines. The kits, which contain four Fine Tuner assemblies, are intended for single channels or two adjacent channels in the UHF TV frequency band. In some cases, they may provide some improvement at the upper VHF TV channel frequencies (Channels 7 to 13), but their use for the lower VHF TV frequencies and FM is not recommended.

Download File

Grounding Kit For HELIAX® Elliptical Waveguide and Coaxial Cable

Installation Instructions - Grounding Kit For HELIAX® Elliptical Waveguide and Coaxial Cable

Download File

Hangers for 1-5/8″ Rigid Transmission Line, Types RLA100-13-2, RLA100-11-H, and 14378

The hangers are designed to mount 1-5/8" rigid transmission line on a steel tower or other support structure and to accommodate the differential expansion and contraction between the line and the tower

Download File

Hinged Spring and Rigid Hangers for 3-1/8″ Rigid Transmission Line; Types RLA300-11-H, RLA300-13, and RLA300-13A

Type RLA300-13 rigid hanger is designed for mounting 3- 1/8" rigid transmission line. One hanger will anchor up to 300 ft (90 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 300 ft (90 m) of line or portion thereof. Type RLA300-11-H hinged vertical spring hanger is used to support the weight and accommodate the differential expansion of 3-1/8" rigid transmission line.

Download File

Hinged Spring and Rigid Hangers for 4-1/16″ Rigid Transmission Line Types RLA400-11-H, RLA400-13 and RLA400-13L

Type RLA400-13 rigid hanger is designed for mounting 4-1/16" ERI rigid transmission line with an outside diameter of 4.13 inches (105 mm). One hanger will anchor up to 1000 ft (300 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 1000 ft (300 m) of line or portion thereof. Type RLA400-13L rigid hanger is designed for mounting 4-1/16" rigid transmission line. One hanger will anchor up to 500 ft (150 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 500 ft (150 m) of line or portion thereof. Type RLA400-11-H hinged vertical spring hanger is used to support the weight and accommodate the differential expansion of 4-1/16" rigid transmission line.

Download File

Hinged Spring and Rigid Hangers for 7-3/16″ Transmission Line Types RLA700-11-H and RLA700-13

Type RLA700-13 rigid hanger is designed for mounting 7-3/16" ERI rigid transmission line with an outside diameter of 7.15 inches (182 mm). One hanger will anchor up to 1000 ft (300 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 1000 ft (300 m) of line or portion thereof. Type RLA700-11-H hinged vertical spring hanger is used to support the weight and accommodate the differential expansion of 7-3/16" rigid transmission line.

Download File

Hinged Spring and Rigid Hangers for 8-3/16″ Transmission Line Types RLA800-11-H and RLA800B-13

Type RLA800B-13 rigid hanger is designed for mounting 8-3/16" ERI rigid transmission line with an outside diameter of 8.15 inches (207 mm). One hanger will anchor up to 1000 ft (300 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 1000 ft (300 m) of line or portion thereof. Type RLA800-11-H hinged vertical spring hanger is used to support the weight and accommodate the differential expansion of 8-3/16" rigid transmission line.

Download File

Hinged Spring and Rigid Vertical Hangers for 3-1/8” Rigid Transmission Line Types RLA300-11A and RLA300-13A

Type RLA300-13A rigid vertical hanger is designed for anchoring 3-1/8 inch rigid coaxial transmission line. One hanger will support up to 300 ft (90 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 300 ft (90 m) of line or portion thereof. Type RLA300-11A hinged spring vertical hanger is used to support the weight, provide lateral restraint, and accommodate the differential expansion of the rigid transmission line.

Download File

Hinged Vertical Spring and Rigid Hangers For 6-1/8 inch Rigid Coaxial Transmission Line Types RLA600-11-H, RLA600B-13, and RLA600-13L

Type RLA600-13 rigid hanger is designed for mounting 6-1/8 inch rigid coaxial transmission line. One hanger will anchor up to 1000 ft (300 m) of transmission line. One additional hanger should be used on the top section of the vertical run for every additional 1000 ft (300 m) of line or portion thereof. Type RLA600-13L light duty rigid hanger is designed for mounting 6-1/8 inch rigid transmission line. Two hangers mounted 5 feet apart on the top section of the vertical line run will anchor up to 500 feet (150 m) of transmission line. Three hangers each mounted 5 feet apart will secure up to 1000 feet (300 m) of transmission line. Hanger mount is slotted for use with both 2-3/8 and 2-1/2 inch bolt spacing. Type RLA600-11-H hinged vertical spring hanger is used to support the weight and accommodate the di erential expansion of 6-1/8 inch rigid transmission line. Hanger mount is slotted for use with both 2-3/8 and 2-1/2 inch bolt spacing.

Download File

Horizontal Suspension Hangers for 3-1/8″, 4-1/16″, 6-1/8″, 7-3/16″, and 8-3/16″ Transmission Lines; Types RLA300-12, RLA300-12SP, RLA400-12, RLA400-12SP,RLA600-12, RLA600-12SP, RLA700-12, RLA700-12SP, RLA800-12,RLA800-12SP

Types RLA300-12, RLA300-12SP, RLA400-12, RLA400- 12SP, RLA600-12, RLA600-12SP, RLA700-12, RLA700- 12SP, RLA800-12 and RLA800-12SP Horizontal Suspension Hangers are designed for use with 3-1/8", 4- 1/16", 6-1/8", 7-3/16", and 8-3/16" transmission lines, respectively. Suspension hangers are usually attached along horizontal transmission line runs at approximately 10 ft (3 m) spacing to allow vertical movement caused by the differential expansion/contraction of the transmission line. Types RLA___-12SP hangers do not control side movement, because they are used when there is not enough room to use the hangers listed in the paragraph above. Others are responsible for installing appropriate equipment to control side to side movement of the rigid line.

Download File

Inner Conductor Only for MACXLine® Rigid Coaxial Transmission Lines Type MACX650-26

Type MACX650-26 field kits are used for field trimming inner conductors to a non-standard length between 5 and 20 feet.The MACX650-26 kits are complete with bullet/bellows assembly, insulators, and hardware kit.The inner conductor supplied has provisions to attach the bullet/bellows assembly to either end.This feature eliminates the need to solder a stub to the inner when the length requirement interferes with the disk insulators.The inner conductor is marked with black ink to designate specific areas where cutting requires a special procedure.The outer lengths requiring the special procedure are 165.13 – 161.13 inches and 85.88 – 81.88 inches. Outer conductor lengths outside of these two ranges do not require the special procedure.The "Special Procedure" involves the disassembly of the bullet/bellows assembly and installing it on the other end of the inner conductor.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Line Type MACX350-25-(*)

MACXLIne® inner conductors are factory trimmed according to the specified outer conductor length. No field cutting is required. Inner conductors must be installed with the bellows and captivated inner connector towards the antenna.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Type MACX350-26

Type MACX350-26 Inner Conductor Kits are used for field trimming inner conductors to a nonstandard length between 5 and 20 feet.Type MACX350-26 Inner Conductors are supplied as an entire 20 ft inner conductor sec tio with bellows, Insulators, captivating Inner connector and hardware kit. The Inner conductor must be field cut °Prent re to the desired length to mate with the corresponding outer conductor. The inner conductor is marked with black ink to designate specific areas where cutting must not take place. The overall end result Is, after cutting, to produce a field trimmed inner conductor that contains Bellows the bellows and at least one insulator.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Type MACX650-25-(240, 237, 234, 228)

MACXLine inner conductors are factory trimmed according to the specified outer conductor length. No field cutting is required. Install inner conductors with the bellows and captivated inner connector toward the antenna.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Type MACX675B-25-(1, 2, 3, 6) and MACX450-25-(1, 2, 3, 6)

MACXLine® inner conductors are factory trimmed according to the specified outer conductor length. No field cutting is required. Install inner conductors with the bellows and captivated inner connector toward the antenna.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Type MACX775-25-(240, 237, 234, 228)

MACXLine inner conductors are factory cut to match the specified outer conductor length. No field cutting should be undertaken. The inner conductor is installed with its bellows and captivated inner connector at the antenna end of the line section.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Types MACX350A-24, MACX450-24, and MACX675A-24

Types MACX350A-24, MACX450-24, and MACX675A- 24 Inner Conductor Kits are used for field trimming inner conductors to non-standard lengths of less than five feet. The inner conductors are supplied as a five foot inner conductor section with captivating inner connector and hardware kit. The inner conductor must be field cut to the desired length to mate with the corresponding outer conductor.

Download File

Inner Conductors for MACXLine® Rigid Coaxial Transmission Lines Types MACX675B-25-(1, 2, 3, 6, 11) and MACX450-25-(1, 2, 3, 6, 11)

ERI MACXLine inner conductors are factory trimmed according to the specified outer conductor length. No field cutting is required. Inner conductors are installed with the bellows and captivated inner connector toward the antenna.

Download File

Installation Instructions – Gas Barriers For Coaxial Cables and Rigid Transmission Lines Types RLA050-, RLA150-, RLA350-, RLA450-, RLA650-, RLA675-, RLA775-, & RLA875- 16

The Gas Barriers in this series are designed for use with transmission lines and cables. Type RLA150-16 has one gas port that enters the barrier on the pressurized side of the insulator. The others have two or more gas ports.

Download File

Insulated Hangers for 1-1/4″, 1-5/8″, 2-1/4″, 3″, 4″, and 5″ Coaxial Cables

The insulated hanger kits contain a hanger, insulator, and the hardware necessary to mount 1-1/4", 1-5/8", 2-1/4", 3", 4", and 5" semiflexible coaxial cables. Where a mounting adapter is required, the mounting hardware is part of the adapter.

Download File

Insulated Hangers for 1/4″, 3/8″, 1/2″, and 7/8″ Coaxial Cables

These hangers are designed for mounting coaxial cable to steel towers or other support structures. The hanger is used to isolate the cable from the tower when the cable feeds an antenna mounted on an AM broadcast tower. The Type 11662-3 hanger includes shims appropriate for use with 1/4", 3/8", and 1/2" cables. The 11662-2 hanger is used for 7/8" cable. Hangers must be spaced no more that 3 feet (0.9 m) apart.

Download File

Lateral Braces for 3-1/8″, 4-1/16″, 6-1/8″, 7-3/16″, and 8-3/16″ Transmission Lines; Types RLA300-14, RLA400-14, RLA600-14, RLA700-14, and RLA800-14

A lateral brace is required on the lower portion of the vertical transmission line run to restrict lateral motion while allowing for vertical and horizontal line movement.

Download File

MACXLine® 4-1/16″ 50 ohm Rigid Coaxial Transmission Line Type MACX450

ERI MACX450 Rigid Coaxial Transmission Line is used to provide an outdoor, high-power signal path between TV and FM transmitters and the broadcast antennas. The antenna end of each MACXLine section inner conductor is provided with a bellows to compensate for thermal expansion and to prevent wear and the eventual failure of the section to section connection.

Download File

MACXLine® 4-1/16″ Rigid Coaxial Transmission Line

Transmission line is designed to provide high power signal path between transmitter combiner and broadcast antenna. Corrugated bellows are provided at one end of the inner conductor to compensate for differential expansion between inner and outer conductor as the transmission line is heated during operation.

Download File

MACXLine® 6-1/8″ Rigid Coaxial Transmission Line

Transmission line is designed to provide a high power signal path between transmitter combiner and broadcast antenna. Corrugated bellows are provided at one end of the inner conductor to compensate for differential expansion between inner and outer conductor as the transmission line is heated during operation. A lockout screw and handle is factory installed to lock the bellows assembly at its maximum travel. The lockout screw is engaged for shipping and aids in the proper insertion of the inner conductor into the inner conductor tube. Remove and discard the locking screw/handle after installation of each section.

Download File

MACXLine® 7-3/16″ Rigid Coaxial Transmission Line

Transmission line is designed to provide high power signal path between transmitter combiner and broadcast antenna. Corrugated bellows are provided at one end of the inner conductor to compensate for differential expansion between inner and outer conductor as the transmission line is heated during operation.

Download File

MACXLine® 8-3/16″ Rigid Coaxial Transmission Line Including Inners Only™ Replacement Systems

Insatllation Instructions - MACXLine® 8-3/16" Rigid Coaxial Transmission Line Including Inners Only™ Replacement Systems

Download File

MACXLine® Inner Conductors for Marmon Flanged Rigid Coaxial Transmission Lines Type MACX350-29-(*)

MACXLine® inner conductors are factory trimmed according to the specified outer conductor length. No field culling is required. Inner conductors must be installed with the bellows and captivated inner connector towards the antenna.

Download File

MACXLine® Inner Conductors for Marmon Flanged Rigid Coaxial Transmission Lines Type MACX350-31 Field Cut

Type MACX350-31 Inner Conductor Kits are used for field trimming inner conductors to a nonstandard length between 5 and 20 feet. Type MACX350-31 Inner Conductors are supplied as an entire 20 ft inner conductor section with bellows, insulators, captivating inner connector and hardware kit.The inner conductor must be field cut to the desired length to mate with the corresponding outer conductor.The inner conductor is marked with black ink to designate specific areas where cutting must not take place.The overall end result is, after cutting, to produce a field trimmed inner conductor that contains the bellows and at least one insulator.

Download File

MACXLine® Rigid Coaxial Transmission Line

Installation Instructions for MACXLine® rigid transmission line sizes: 3-1/8-inch, 4-1/16-inch, 6-1/8-inch (50-ohm and 75-ohm), 7-3/16-inch, and 8-3/16-inch and the associated ERI manufactured hangers and other support products and accessories applicable to these systems.

Download File

MACXLine® Rigid Coaxial Transmission Lines Type MACX675B-(1,2,3,6)

Installation Instructions - MACXLine® Rigid Coaxial Transmission Lines Type MACX675B-(1,2,3,6)

Download File

MACXLine® Rigid Line Less than 5-Foot Lengths Types MACX350A-41 and MACX675B-41

Types MACXL350A-41 and MACX675B-41 Rigid Line Field Kits are used for field trimming to nonstandard lengths of less than 5 feet. The Field Kits are supplied with an outer conductor with one flange attached, fixed field flange (for attachment), 5 ft inner conductor, captivated inner connector, and hardware kit. The inner and outer conductors must be field cut to the desired length to fit into the rigid line installation. The outer conductor must be trimmed and the fixed flange soldered to the cut end.

Download File

Male-to-MaleAdapters For Flanged Transmission Line Components Types STD050-52, STD150-52, STD350-52, STD450-52, STD650-52, STD675-52, STD775-52, STD875-52, CA405, CA605, and CA705

These adapters are designed to join two coaxial transmission line components having captivated inner connectors. Such components include ex sections, gas barriers, and coaxial cable connectors. Includes one ange hardware kit, but no inner connectors. Types CA405, CA605, and CA705 are also for male to male connections, but are speci cally designed to connect Dieliectric thin-walled inner conductor to ERI for the same nominal coaxial line size.

Download File

Rigid Coaxial Transmission Line Types MACX350A

Installation Instructions - Rigid Coaxial Transmission Line Types MACX350A

Download File

RIGID HORIZONTAL HANGERS For Rigid Coaxial Transmission Lines Type RLA300-17 and RLA400-17

ERI Types RLA300-17 and RLA400-17 Horizontal Rigid Hangers are used for supporting a horizontal run of Rigid Coaxial Transmission Line between the transmitter building and the antenna tower. The hangers prevent lateral or vertical movement of the line, but allow some longitudinal movement.

Download File

RIGID HORIZONTAL HANGERS For Rigid Coaxial Transmission Lines Type RLA600-17 and RLA700-17

ERI Types RLA600-17, RLA700-17, and RLA800-17 Horizontal Rigid Hangers are used for supporting a horizontal run of Rigid Coaxial Transmission Line between the transmitter building and the antenna tower. The hangers prevent lateral or vertical movement of the line, but allow some longitudinal movement.

Download File

Soft Solder Field Flange Kits For Rigid Coaxial Transmission Lines Types RLA000-37, RLA100-37, RLA300-37, RLA400-37, RLA600B-37, RLA700-37, and RLA800B-37

The Soft Solder Field Flange kits in this series are designed for use with Standard rigid coaxial transmission line. They may also be used with MACXLine®, but the cutback dimensions must be taken from MACXLine® Bulletins. The kits each include a fixed ring, a swivel flange, and rosin core solder or solder with flux. ERI Installation Bulletin II23006-SS1.

Download File

Standard Rigid Coaxial Transmission Lines for Types STD050, STD150, STD350, STD450, STD650B, STD675B, STD775, and STD875

Installation Instructions - Standard Rigid Coaxial Transmission Lines from 7/8-inch through 8-3/16-inch For Type Numbers STD050, STD150, STD350, STD450, STD650B, STD675B, STD775, and STD875.

Download File

Supported Miter Elbows For Standard and MACXLine® Coaxial Transmission Lines Types ACX050-10SE, ACX150-10SE, ACX350-10SE, ACX350-9SE, ACX350-10SU, ACX450-10SE, ACX450-10SU, ACX450-9SE, ACX650B-10SE, ACX650B-10SU, ACX675B-10SU-(*), ACX775-10SE-(*), ACX775-9SE-(*), and ACX875B-10ASE

Supported Miter Elbows For Standard and MACXLine® Coaxial Transmission Lines Types ACX050-10SE, ACX150-10SE, ACX350-10SE, ACX350-9SE, ACX350-10SU, ACX450-10SE, ACX450-10SU, ACX450-9SE, ACX650B-10SE, ACX650B-10SU, ACX675B-10SU-(*), ACX775-10SE-(*), ACX775-9SE-(*), and ACX875B-10ASE

Download File

Swivel and Fixed Flange Kits For Rigid Coaxial Transmission Lines Types RLA000-, RLA100-, RLA300-, RLA400-, RLA600B-, RLA700-, & RLA800B- 27 and 28

The kits in this series are for use with all ERI rigid coaxial lines. The kits include flange components, silver solder, and solder flux.

Download File

Unflanged Couplings Types RLA050-39A, RLA150-39A, 1329150-39A, RLA350-39A, 1329350-39A, RLA450-39A, 1329450-39A, RLA650-39, and 1329650-39

The Types RLA050-39A, RLA150-39A, 1329150-39A, RLA350-39A, 1329350-39A,RLA450-39A, 1329450-39A, RLA650-39, and 1329650-39 unpressurized couplings are made for use with 50-Ohm, 7/8”, 1-5/8", 3-1/8", 4-1/16”, and 6-1/8” copper and aluminum outer conductor transmission lines, respectively, and are designed to connect unflanged line sections. The outer conductors are held in place with a coupling sleeve and clamps, while the inner conductors are joined by an inner connector. The couplings do not hold gas pressure and are recommended for indoor use only.

Download File

Universal Spring Hanger for ERI Rigid Transmission Line Combiners Type RLA000-18

ERI Type RLA000-18 Universal Spring Hanger is designed for supporting tower-mounted combiners and similar components attached to ERI rigid transmission line. It allows for up to ± 3 inches of vertical movement of the load due to thermal expansion of the line. One hanger will support a load between 50 and 125 pounds. For loads greater than 125 pounds, additional hangers may be used in parallel.

Download File

Wall/Roof Feed Thru Kits For HELIAX® Coaxial Cables, Types 40394-1, 40394-2

Types 40394-1 and 40394-2 Wall/Roof Feed Thru Kits provide a weatherproof path through a wall or roof for HJ11-50 and HJ8-50B coaxial cables, respectively. A kit can be mounted to a metal or concrete wall or roof and has eight 3/8 in (10 mm) diameter mounting holes. Each kit consists of a feed-thru plate, rubber boot, adjustable hose clamps, a roll of sealing tape, lock washers, and flat washers.

Wall/Roof Feed-Thru Plates for Rigid Transmission Line Types RLA300-15, RLA400-15, RLA600-15, RLA600B-15-2, RLA700-15, and RLA800B-15

Feed-thru plates seal rigid line access entry points on buildings. The feed-thru plates are split matched halves with a total of eight mounting holes using hardware (not included).

Download File

WIDELine™ 6-1/8” Rigid Coaxial Transmission Line

WIDELine™ 6-1/8” coaxial transmission line is designed and manufactured to provide a high reliability, broad band, low VSWR, high power, signal path between a TV transmitter combiner and broadcast antenna. Bellows at the upper end of the inner conductor compensate for differential thermal expansion between inner and outer conductors to prevent bullet wear. A wing screw is factory installed to lock the bellows assembly at its maximum travel during shipping and installation. This screw ensures proper bedding of each section's inner conductor on the lower bullet thus minimizing its VSWR contribution. Remove and discard this screw, after installation of the section.

Download File

WIDELine™ 7-3/16″ Rigid Coaxial Transmission Line

WIDELine™ 7-3/16" coaxial transmission line is designed and manufactured to provide a high reliability, broad band, low VSWR, high power, signal path between a TV transmitter combiner and broadcast antenna. Bellows at the upper end of the inner conductor compensate for differential thermal expansion between inner and outer conductors to prevent bullet wear. A wing screw is factory installed to lock the bellows assembly at its maximum travel during shipping and installation.This screw ensures proper bedding of each section's inner conductor on the lower bullet thus minimizing its VSWR contribution. Remove and discard this screw, after installation of the section.

Download File

WIDELine™ Elbows for ACX650-10E-W Rigid Transmission Line

Installation Instructions - WIDELine™ Elbows for ACX650-10E-W Rigid Transmission Line

Download File